Demonstration oscilloscope U8481350
Instruction sheet
01/08 CW/ALF
Inputs:
1 Anode voltage
2 Cathode voltage
3 Wehnelt (focussing) voltage
4 Heater voltage (0)
5 Heater voltage (+)
6 Chassis ground
7 Deflecting plate (left)
8 Deflecting plate (right)
Outputs:
9 Saw-tooth generator (-)
10 Saw-tooth generator (+)
11 Deflecting coils
12 Circular magnet (obscured by
deflection coil)
13 Cathode ray tube
14 Metal ring
15 Coarse adjustment for saw-
tooth frequency
16 Fine adjustment saw-tooth
frequency
1. Safety instructions
The demonstration oscilloscope is operated with volt-
ages, some of which are above 60 V.
Always turn off power supply before making con-
nections.
Use safety leads.
Since the glass tube is evacuated, there is an implo-
sion hazard.
Do not subject the tube to sharp blows or me-
chanical stress.
In schools and training institutions, operation of the
device is to be responsibly supervised by trained per-
sonnel.
2. Description
The demonstration oscilloscope can be used to show
the deflection of an electron beam by electric and
magnetic fields, just as employed in TVs or conven-
tional oscilloscopes. Essentially, it consists of a cath-
ode ray tube that is supplied with voltage via 4-mm
plugs and is surrounded by a ring, to which deflecting
coils can be attached.
A cathode ray tube is an evacuated glass tube, the
neck of which contains a heated cathode and an an-
ode in the shape of a disc with a hole in the middle,
separated by a distance of approximately half a cen-
timetre. Electrons emitted from the heated cathode
are accelerated towards the anode. Some of them
pass through the hole to form a beam that strikes the
fluorescent screen (with zinc silicate coating) and thus
becomes visible as a green fluorescent dot. The beam
is focussed partly by a Wehnelt cylinder surrounding
the cathode, the potential of which is negative with
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - PHYSICS

3B SCIENTIFIC® PHYSICS 1 Demonstration oscilloscope U8481350 Instruction sheet 01/08 CW/ALF Inputs: 1 Anode voltage 2 Cathode voltage 3

Page 2

2 respect to the cathode potential, and partly by gas constriction as a result of the tube being filled with neon at a pressure of 0.01 mm Hg that als

Page 3

3 tions, a saw-tooth generator is used to supply this voltage. In this case, the beam goes from left to right and then quickly flicks back again. This

Page 4

4 • With the fine adjustment, search for a frequency at which a standing image appears, which shows a clear period of oscillation. At which other saw

Page 5

5 Fig.3 Magnetic deflection of the electron beam (left: with power supply U8521371 and power supply U33020, right: with power supply U33000)

Page 6

Elwe Didactic GmbH • Steinfelsstr. 6 • 08248 Klingenthal • Germany • www.elwedidactic.com 3B Scientific GmbH • Rudorffweg 8 • 21031 Hamburg • Germany