User’s ManualChester Chest™Model 2400308 South Sequoia Parkway, Canby, Oregon 97013 USAph. 503.651.5050 | fax 503.651.5052 | email info
www.vatainc.comfig. 190420 0430 0440Difficult Accessing InsertsThe model is supplied with three different Difcult Accessing Inserts. These are used alo
www.vatainc.comDIFFICULT ACCESSING INSERT 0430 for simulation of a normal or “tipping” port. This insert is in place, under the port, when yo
Chester ChestTM Refurbishing Service The purchase of training models is a significant financial investment. Realizing this, VATA is proud to offer a ref
www.vatainc.comThank you for your purchase of a Chester Chest™ Model 2400 with the New Advanced Arm 2386. Chester Chest™, an industry standard since
www.vatainc.comChester Chest™ - with the New Advanced Arm (arm can be ordered separately to upgrade your existing Chester Chest™). The New Advanced Ar
www.vatainc.comThese catheters are available from VATA – see Supplies and Accessories section page 12. If you would prefer, you can send us the cathet
www.vatainc.com1 0406 Real Port (IVAD)2 0407 Tunneled Cental Catheter 9.6FR3 Base4 0405 Outer Tissue Pad5 0451 Simulated “Blood” Reservior Bag for Tor
www.vatainc.comUnwrap the arm and body. Set the bag of additional parts, packed with the torso, aside for use later. Place the torso on a flat sur
www.vatainc.comfig. 9fig. 10fig. 11Afig. 12fig. 11BThen remove the Chest Tissue Flap on the left side of the chest (do not place on printed papers
www.vatainc.comChest Tissue Flap - 0405When removing the Chest Tissue Flap, always pull gently from the edge to prevent damage to the ap. Due to the
www.vatainc.comWhen accessing through the flap, a 22g Huber-type needle is best. Be sure to check the needle tip periodically for burrs.